{"id":4341,"date":"2026-10-22T16:06:34","date_gmt":"2026-10-22T16:06:34","guid":{"rendered":"https:\/\/www.savioclima.com\/?p=4341"},"modified":"2026-10-23T09:21:34","modified_gmt":"2026-10-23T09:21:34","slug":"50-hz-vs-60-hz-fans","status":"publish","type":"post","link":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/","title":{"rendered":"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Most of the world runs on 50 Hz. The USA, Canada and part of Latin America run on 60 Hz. For a fan this is not a detail: the same impeller on the same motor turns 20% faster on 60 Hz, and airflow, pressure, power and noise all change with it. This guide explains what changes, why a 50 Hz fan must never simply be connected to a 60 Hz supply, and how to get a correct selection for North America.<\/p>\n\n<h2 class=\"wp-block-heading\">1. Frequency sets the motor speed<\/h2>\n\n<p class=\"wp-block-paragraph\">The speed of an induction motor depends on the supply frequency and the number of poles:<\/p>\n\n<p class=\"has-background wp-block-paragraph\" style=\"background-color:#EEF4F8;padding-top:14px;padding-right:20px;padding-bottom:14px;padding-left:20px\"><code>Synchronous speed (rpm) = 120 \u00d7 frequency (Hz) \u00f7 number of poles<\/code><\/p>\n\n<p class=\"wp-block-paragraph\">Under load the motor runs a few percent below synchronous speed (the slip). Typical values:<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Poles<\/th><th>50 Hz synchronous<\/th><th>50 Hz typical at load<\/th><th>60 Hz synchronous<\/th><th>60 Hz typical at load<\/th><\/tr><\/thead><tbody><tr><td>2<\/td><td>3,000<\/td><td>\u2248 2,900<\/td><td>3,600<\/td><td>\u2248 3,500<\/td><\/tr><tr><td>4<\/td><td>1,500<\/td><td>\u2248 1,450<\/td><td>1,800<\/td><td>\u2248 1,750<\/td><\/tr><tr><td>6<\/td><td>1,000<\/td><td>\u2248 960<\/td><td>1,200<\/td><td>\u2248 1,160<\/td><\/tr><tr><td>8<\/td><td>750<\/td><td>\u2248 720<\/td><td>900<\/td><td>\u2248 870<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">2. The fan laws: what happens at 20% more speed<\/h2>\n\n<p class=\"wp-block-paragraph\">For the same fan and the same air density, performance follows the fan laws:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>Airflow<\/strong> changes with speed: CFM\u2082 = CFM\u2081 \u00d7 (N\u2082 \u00f7 N\u2081)<\/li>\n\n<li><strong>Static pressure<\/strong> changes with the square of speed: SP\u2082 = SP\u2081 \u00d7 (N\u2082 \u00f7 N\u2081)\u00b2<\/li>\n\n<li><strong>Power<\/strong> changes with the cube of speed: HP\u2082 = HP\u2081 \u00d7 (N\u2082 \u00f7 N\u2081)\u00b3<\/li>\n\n<li><strong>Sound power<\/strong> rises by about 50 \u00d7 log\u2081\u2080(N\u2082 \u00f7 N\u2081) dB<\/li>\n<\/ul>\n\n<h3 class=\"wp-block-heading\">Example<\/h3>\n\n<p class=\"wp-block-paragraph\">A 4-pole fan selected on 50 Hz delivers <strong>20,000 CFM at 1.0 in. w.g.<\/strong> at 1,450 rpm and absorbs <strong>6 HP<\/strong>. Connected to 60 Hz, it turns at about 1,750 rpm (ratio 1.21):<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Quantity<\/th><th>50 Hz<\/th><th>60 Hz<\/th><th>Change<\/th><\/tr><\/thead><tbody><tr><td>Speed<\/td><td>1,450 rpm<\/td><td>1,750 rpm<\/td><td>+21%<\/td><\/tr><tr><td>Airflow<\/td><td>20,000 CFM<\/td><td>\u2248 24,100 CFM<\/td><td>+21%<\/td><\/tr><tr><td>Static pressure<\/td><td>1.0 in. w.g.<\/td><td>\u2248 1.46 in. w.g.<\/td><td>+46%<\/td><\/tr><tr><td>Absorbed power<\/td><td>6 HP<\/td><td>\u2248 10.5 HP<\/td><td>+76%<\/td><\/tr><tr><td>Sound power<\/td><td>reference<\/td><td>\u2248 +4 dB<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">The fan now moves more air than needed, the motor is badly overloaded, the impeller tip speed may exceed its mechanical limit, and the unit is noticeably louder. More airflow is not a bonus: the motor and the impeller were never designed for it.<\/p>\n\n<h2 class=\"wp-block-heading\">3. Three correct ways to handle 60 Hz<\/h2>\n\n<ol class=\"wp-block-list\">\n<li><strong>Reselect on 60 Hz curves.<\/strong> The fan is chosen again for the required operating point at 60 Hz speed. This often means a different diameter or a different number of poles: a 6-pole motor at about 1,160 rpm on 60 Hz turns roughly 20% slower than a 4-pole on 50 Hz.<\/li>\n\n<li><strong>Adjust the blade pitch.<\/strong> On adjustable-pitch axial fans such as <a href=\"https:\/\/www.savioclima.com\/en\/2023\/10\/23\/si-sir\/\">SI \/ SIR<\/a>, a lower blade angle brings airflow and power back to the design point at 60 Hz speed, with the same impeller and housing.<\/li>\n\n<li><strong>Use a VFD.<\/strong> A variable frequency drive can run the fan at the speed it needs, regardless of the supply. The motor must be inverter-duty and the drive must be included in the scope and the price.<\/li>\n<\/ol>\n\n<p class=\"wp-block-paragraph\">What is not acceptable: shipping a 50 Hz selection and connecting it to a 60 Hz supply, hoping the motor will cope.<\/p>\n\n<h2 class=\"wp-block-heading\">4. Motors for the USA and Canada<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Item<\/th><th>What to check<\/th><\/tr><\/thead><tbody><tr><td>Voltage<\/td><td>USA: 460 V three-phase is the standard industrial voltage (208 V and 230 V on smaller units). Canada: 575 V is common in industrial plants.<\/td><\/tr><tr><td>Listing<\/td><td>Motors UL or CSA listed (cURus \/ CSA marking) for acceptance by inspectors and OEM customers.<\/td><\/tr><tr><td>Efficiency<\/td><td>US DOE rules (10 CFR Part 431) set premium efficiency levels for most general-purpose motors. Check whether your application is covered.<\/td><\/tr><tr><td>Enclosure<\/td><td>TEFC for outdoor or dusty duty; IP55 is the usual IEC equivalent.<\/td><\/tr><tr><td>Frame<\/td><td>NEMA-frame or IEC-frame motors. Many OEMs accept IEC frames with UL \/ CSA listing; where the specification calls for NEMA motors, they are available.<\/td><\/tr><tr><td>Service factor<\/td><td>NEMA motors are often rated with a 1.15 service factor, IEC motors usually 1.0. Size the motor on the fan power, not on the service factor.<\/td><\/tr><tr><td>VFD duty<\/td><td>For drive operation, inverter-duty insulation according to NEMA MG 1 Part 31.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">5. Performance data and testing<\/h2>\n\n<p class=\"wp-block-paragraph\">Specifications in North America often refer to fan performance tested according to <strong>AMCA 210<\/strong> (airflow and pressure) and <strong>AMCA 300<\/strong> (sound). Ask your supplier for curves at 60 Hz speed and at your air density, and for the test basis behind them. If a project specification requires the <strong>AMCA Certified Ratings Seal<\/strong>, make it clear at the inquiry stage, because it is a separate certification program.<\/p>\n\n<h2 class=\"wp-block-heading\">6. Checklist when converting a 50 Hz project to 60 Hz<\/h2>\n\n<ul class=\"wp-block-list\">\n<li>Required airflow and static pressure at site conditions (not the 50 Hz values scaled up)<\/li>\n\n<li>Air temperature, altitude and resulting density<\/li>\n\n<li>Supply voltage and frequency; direct-on-line or VFD<\/li>\n\n<li>Motor listing (UL \/ CSA), efficiency class, enclosure and frame standard<\/li>\n\n<li>Maximum allowed sound level at a given distance<\/li>\n\n<li>Space available: diameter, length, mounting<\/li>\n\n<li>Hazardous area classification, if any<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">How SAVIO handles North American projects<\/h2>\n\n<p class=\"wp-block-paragraph\">SAVIO has built industrial fans in Italy since 1945. For the USA and Canada we select every fan on <strong>60 Hz performance curves<\/strong>, supply <strong>UL \/ CSA motors at 460 V and 575 V<\/strong>, in NEMA or IEC frames, and verify performance in our in-house test room built to AMCA standards. Our axial fans cover 12&#8243; to 63&#8243; and up to 88,000 CFM per unit, with adjustable-pitch blades on the SI \/ SIR series to match the operating point exactly.<\/p>\n\n<p class=\"wp-block-paragraph\">See also <a href=\"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/genset-radiator-fan-sizing\/\">Genset Radiator Fans: How to Size Airflow and Static Pressure<\/a>, <a href=\"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/tubeaxial-vs-vaneaxial-vs-propeller-fans\/\">Tubeaxial vs Vaneaxial vs Propeller Fans<\/a> and our page <a href=\"https:\/\/www.savioclima.com\/en\/axial-fans-usa-canada\/\">Industrial Axial Fans for the USA and Canada<\/a>.<\/p>\n\n<div class=\"wp-block-group cta-preventivo is-layout-flow wp-block-group-is-layout-flow\" style=\"background-color:#043751;padding:30px\">\n<h3 class=\"wp-block-heading\" style=\"color:#ffffff\">Converting a project to 60 Hz?<\/h3>\n\n<p class=\"wp-block-paragraph\" style=\"color:#ccddea\">Send us the operating point and the supply voltage: we will reply with a 60 Hz selection and a quote.<\/p>\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-text-color has-background\" href=\"https:\/\/www.savioclima.com\/en\/axial-fans-usa-canada\/#richiesta-offerta\" style=\"border-radius:4px;background-color:#ffffff;color:#043751\"><strong>Request 60 Hz data<\/strong><\/a><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Why a 50 Hz fan must not simply be connected to a 60 Hz supply: motor speed, fan laws, three correct ways to handle 60 Hz, and motor requirements for the USA and Canada.<\/p>\n","protected":false},"author":5,"featured_media":820,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[140],"tags":[],"class_list":["post-4341","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"gianluca\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Savio Clima - Industrial Fans and Blowers\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO\" \/>\n\t\t<meta property=\"og:description\" content=\"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"442\" \/>\n\t\t<meta property=\"og:image:height\" content=\"106\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-10-22T16:06:34+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-23T09:21:34+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO\" \/>\n\t\t<meta name=\"twitter:description\" content=\"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#blogposting\",\"name\":\"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\\\/CSA | SAVIO\",\"headline\":\"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America\",\"author\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/author\\\/gianluca\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/savio-clima-SI.jpg\",\"width\":1200,\"height\":980,\"caption\":\"Ventilatori assiali Savio Clima\"},\"datePublished\":\"2026-10-22T16:06:34+00:00\",\"dateModified\":\"2026-10-23T09:21:34+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#webpage\"},\"articleSection\":\"News\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/category\\\/news\\\/#listItem\",\"name\":\"News\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/category\\\/news\\\/#listItem\",\"position\":2,\"name\":\"News\",\"item\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/category\\\/news\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#listItem\",\"name\":\"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#listItem\",\"position\":3,\"name\":\"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/category\\\/news\\\/#listItem\",\"name\":\"News\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#organization\",\"name\":\"Savio Clima\",\"description\":\"Industrial Fans and Blowers\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/\",\"email\":\"savio@savioclima.it\",\"telephone\":\"+390119591601\",\"foundingDate\":\"1945-06-23\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/wp-content\\\/uploads\\\/2023\\\/09\\\/logo-savio-clima.png\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#organizationLogo\",\"width\":442,\"height\":106},\"image\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/savioclima\\\/?originalSubdomain=it\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/author\\\/gianluca\\\/#author\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/author\\\/gianluca\\\/\",\"name\":\"gianluca\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0b4aef697e0ed98c2e153ef6be86002196bb80efd3f39a9536664e89cd20c154?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"gianluca\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#webpage\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/\",\"name\":\"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\\\/CSA | SAVIO\",\"description\":\"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/author\\\/gianluca\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/author\\\/gianluca\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/savio-clima-SI.jpg\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#mainImage\",\"width\":1200,\"height\":980,\"caption\":\"Ventilatori assiali Savio Clima\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/2026\\\/10\\\/22\\\/50-hz-vs-60-hz-fans\\\/#mainImage\"},\"datePublished\":\"2026-10-22T16:06:34+00:00\",\"dateModified\":\"2026-10-23T09:21:34+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/\",\"name\":\"Savio Clima\",\"description\":\"Industrial Fans and Blowers\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.savioclima.com\\\/en\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO","description":"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.","canonical_url":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#blogposting","name":"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO","headline":"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America","author":{"@id":"https:\/\/www.savioclima.com\/en\/author\/gianluca\/#author"},"publisher":{"@id":"https:\/\/www.savioclima.com\/en\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg","width":1200,"height":980,"caption":"Ventilatori assiali Savio Clima"},"datePublished":"2026-10-22T16:06:34+00:00","dateModified":"2026-10-23T09:21:34+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#webpage"},"isPartOf":{"@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#webpage"},"articleSection":"News"},{"@type":"BreadcrumbList","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/#listItem","position":1,"name":"Home","item":"https:\/\/www.savioclima.com\/en\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/category\/news\/#listItem","name":"News"}},{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/category\/news\/#listItem","position":2,"name":"News","item":"https:\/\/www.savioclima.com\/en\/category\/news\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#listItem","name":"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#listItem","position":3,"name":"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America","previousItem":{"@type":"ListItem","@id":"https:\/\/www.savioclima.com\/en\/category\/news\/#listItem","name":"News"}}]},{"@type":"Organization","@id":"https:\/\/www.savioclima.com\/en\/#organization","name":"Savio Clima","description":"Industrial Fans and Blowers","url":"https:\/\/www.savioclima.com\/en\/","email":"savio@savioclima.it","telephone":"+390119591601","foundingDate":"1945-06-23","logo":{"@type":"ImageObject","url":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/09\/logo-savio-clima.png","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#organizationLogo","width":442,"height":106},"image":{"@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#organizationLogo"},"sameAs":["https:\/\/www.linkedin.com\/company\/savioclima\/?originalSubdomain=it"]},{"@type":"Person","@id":"https:\/\/www.savioclima.com\/en\/author\/gianluca\/#author","url":"https:\/\/www.savioclima.com\/en\/author\/gianluca\/","name":"gianluca","image":{"@type":"ImageObject","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/0b4aef697e0ed98c2e153ef6be86002196bb80efd3f39a9536664e89cd20c154?s=96&d=mm&r=g","width":96,"height":96,"caption":"gianluca"}},{"@type":"WebPage","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#webpage","url":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/","name":"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO","description":"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/www.savioclima.com\/en\/#website"},"breadcrumb":{"@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#breadcrumblist"},"author":{"@id":"https:\/\/www.savioclima.com\/en\/author\/gianluca\/#author"},"creator":{"@id":"https:\/\/www.savioclima.com\/en\/author\/gianluca\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg","@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#mainImage","width":1200,"height":980,"caption":"Ventilatori assiali Savio Clima"},"primaryImageOfPage":{"@id":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/#mainImage"},"datePublished":"2026-10-22T16:06:34+00:00","dateModified":"2026-10-23T09:21:34+00:00"},{"@type":"WebSite","@id":"https:\/\/www.savioclima.com\/en\/#website","url":"https:\/\/www.savioclima.com\/en\/","name":"Savio Clima","description":"Industrial Fans and Blowers","inLanguage":"en-US","publisher":{"@id":"https:\/\/www.savioclima.com\/en\/#organization"}}]},"og:locale":"en_US","og:site_name":"Savio Clima - Industrial Fans and Blowers","og:type":"article","og:title":"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO","og:description":"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.","og:url":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/","og:image":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg","og:image:secure_url":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg","og:image:width":"442","og:image:height":"106","article:published_time":"2026-10-22T16:06:34+00:00","article:modified_time":"2026-10-23T09:21:34+00:00","twitter:card":"summary_large_image","twitter:title":"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO","twitter:description":"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.","twitter:image":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg"},"aioseo_meta_data":{"post_id":"4341","title":"50 Hz vs 60 Hz Fans: Fan Laws, Motors, UL\/CSA | SAVIO","description":"What happens when a 50 Hz fan runs on 60 Hz: +21% airflow, +46% pressure, +76% power. How to reselect, adjust blade pitch or use a VFD, and which motors the USA and Canada require.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"featured","og_image_url":"https:\/\/www.savioclima.com\/wp-content\/uploads\/2023\/10\/savio-clima-SI.jpg","og_image_width":"442","og_image_height":"106","og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":0,"frequency":"default","local_seo":null,"limit_modified_date":false,"created":"2026-10-22 16:02:30","updated":"2026-10-23 09:21:35","ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.savioclima.com\/en\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/www.savioclima.com\/en\/category\/news\/\" title=\"News\">News<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.savioclima.com\/en\/"},{"label":"News","link":"https:\/\/www.savioclima.com\/en\/category\/news\/"},{"label":"50 Hz vs 60 Hz Fans: What Changes When a Fan Runs in North America","link":"https:\/\/www.savioclima.com\/en\/2026\/10\/22\/50-hz-vs-60-hz-fans\/"}],"_links":{"self":[{"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/posts\/4341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/comments?post=4341"}],"version-history":[{"count":2,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/posts\/4341\/revisions"}],"predecessor-version":[{"id":4347,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/posts\/4341\/revisions\/4347"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/media\/820"}],"wp:attachment":[{"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/media?parent=4341"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/categories?post=4341"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.savioclima.com\/en\/wp-json\/wp\/v2\/tags?post=4341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}