Home » BLOWERS » MICO – multistage
Soffiante multistadio MICO SAVIO con motore elettrico su basamento

MICO – multistage

PERFORMANCE
Pressure range (mBar): 150 ÷ 1000
Flow rate range (m3/h): 120 ÷ 4.500
Max. inlet fluid temperature (°C): 100°C
CONSTRUCTION
Impeller type: With backward curved blades, aluminium airfoil blades with galvanised steel or stainless steel discs
Fan casing: Aluminium alloy castings
Execution: Transmission coupling - Execution 12
Finish: RAL 7038 standard painting

MICO multistage centrifugal blowers are high pressure units manufactured by SAVIO in Italy since 1945. Thanks to the intermediate stages forming diffusers and return channels, they reach pressures up to approximately 1,100 mBar with flow rates up to approximately 4,800 m³/h. Available in ATEX version up to zone 1/21.

FLUID:

Suitable for clean air and gases, up to +100 °C.

TYPICAL APPLICATIONS:

The ideal solution for biogas conveying and handling, oxygenation in wastewater treatment tanks, process gas recirculation and burner feeding.

Operating Range

The MICO range comprises 4 sizes (90K, 125, 160, 220), each available from 3 to 8 stages: 24 models covering flow rates up to approximately 4,800 m³/h and pressures up to approximately 1,100 mBar, both in compression and suction.

Operating range of SAVIO MICO 90K, 125, 160 and 220 multistage blowers: flow rate and pressure
SizeStagesMax. flow rate [m³/h]Max. pressure [mBar]Max. vacuum [mBar]Max. power [kW]Weight [kg]
MICO 90K3 – 8~ 1,200~ 850~ 790~ 2475 – 134
MICO 1253 – 8~ 2,200~ 750~ 600~ 65155 – 268
MICO 1603 – 8~ 3,400~ 1,100~ 890~ 120260 – 480
MICO 2203 – 8~ 4,800~ 1,050~ 800~ 190350 – 800
Indicative values from catalogue curves, air at 0 °C and 1013 mBar. Bare shaft weight.

Construction

  • Central body, intermediate stages (diffusers and return channels) and end plates in aluminium, assembled with tie rods
  • Aluminium airfoil impellers, keyed on special steel shaft and statically and dynamically balanced
  • Ball and roller bearings in cast iron housings, with automatic elimination of excess grease
  • Belt and pulley transmission, belt tensioner on motor base and standard protective guard
  • Maximum inlet fluid temperature 100 °C; temperature rise between suction and discharge approximately 50 °C

Special Executions

  • ATEX up to zone 1/21 for explosive gases and atmospheres
  • Dedicated seals for biogas and technical gases
  • High efficiency motors IE3 / IE4 and 60 Hz versions
  • Acoustic enclosure with average reduction of approximately 20 dB(A), also for outdoor installation

Biogas and gases with H₂S

General indications on the hydrogen sulfide content in the treated gas:

  • up to 5,000 ppm of H₂S: standard ATEX construction
  • from 5,000 to 10,000 ppm: anodizing and internal polyurethane coating
  • over 10,000 ppm: we recommend treating the gas upstream of the blower

Temperature, humidity, and shutdown cycles affect durability as much as concentration: for every plant, we evaluate the most suitable solution together with you.

Accessories

Single blower/motor base (MICO 125, 160 and 220) · intake filter · silencers · anti-vibration joints on suction and discharge · safety valve for minimum flow · non-return valve · manual butterfly valve · anchoring anti-vibration mounts.

Applications

  • Booster for cogeneration units, upgrading to biomethane and flare in biogas plants
  • Pneumatic conveying and silo aeration in cement plants
  • Oxygenation of treatment tanks, gas burner feeding, gas line pressurization, drying and cooling

Do you have a specific application?

Our technical department is available to help you choose the most suitable solution — from sizing to delivery.

Cement plant applications: MICO blowers for silo aeration and pneumatic conveying →

Biogas plant applications: MICO blowers as booster for cogeneration units, upgrading to biomethane and flare →

Request a quote for MICO – multistage

Tell us about the application or attach a technical specification, a data sheet or a drawing: we will get back to you with a proposal.