The LCX/LCD side channel blowers are compact compressors and vacuum pumps for small and medium flow rates, ideal where stable pressure or vacuum is required with reduced footprint. They operate in both compression and suction mode, in single-stage or two-stage execution, at 50 or 60 Hz and with inverter.
Main data
- Flow rates from approximately 20 to 1,940 m³/h
- Differential pressure up to 600 mbar (two-stage), vacuum up to approximately −300 mbar
- Installed power from 0.4 to 22 kW, three-phase and single-phase motors
- Operation at 50 Hz, 60 Hz and variable speed with inverter
- Horizontal or vertical mounting (depending on model)
The ATEX version range
SM version compressors at 50 Hz, ATEX certified for zone 2 (gas) and zone 22 (dust). The installed power increases with the required operating pressure.
Single-stage
| Model | Flow rate at Δp 0 [m³/h] | Δp max [mbar] | Flow rate at Δp max [m³/h] | Installed power [kW] |
|---|---|---|---|---|
| LCX 1.10 | 91 | 160 | 39 | 0.37 – 0.55 |
| LCX 1.14 | 122 | 200 | 51 | 0.75 – 1.1 |
| LCX 1.20 | 200 | 260 | 64 | 1.5 – 2.2 |
| LCX 1.28 | 290 | 275 | 129 | 2.2 – 3.0 |
| LCX 1.40 | 420 | 350 | 221 | 4.0 – 7.5 |
| LCX 1.50 | 517 | 400 | 281 | 5.5 – 11.0 |
| LCX 1.70 | 717 | 400 | 430 | 7.5 – 15.0 |
| LCX 1.85 | 850 | 450 | 508 | 7.5 – 18.5 |
| LCD 1.140 | 1.363 | 325 | 920 | 11.0 – 18.5 |
| LCD 1.170 | 1.615 | 275 | 1.218 | 15.0 – 22.0 |
Two-stage
| Model | Flow rate at Δp 0 [m³/h] | Δp max [mbar] | Flow rate at Δp max [m³/h] | Installed power [kW] |
|---|---|---|---|---|
| LCX 2.05 | 52 | 275 | 19 | 0,55 |
| LCX 2.07 | 68 | 350 | 23 | 0.75 – 1.1 |
| LCX 2.10 | 96 | 375 | 42 | 1.1 – 1.5 |
| LCX 2.14 | 135 | 425 | 67 | 2.2 – 3.0 |
| LCX 2.20 | 203 | 450 | 125 | 4.0 – 5.5 |
| LCX 2.25 | 255 | 500 | 177 | 5.5 – 7.5 |
| LCX 2.35 | 354 | 550 | 235 | 5.5 – 9.2 |
| LCX 2.42 | 420 | 600 | 283 | 7.5 – 15.0 |
| LCD 2.50 | 514 | 600 | 358 | 7.5 – 15.0 |
| LCD 2.70 | 713 | 600 | 524 | 11.0 – 18.5 |
| LCD 2.85 | 846 | 525 | 671 | 15.0 – 22.0 |
Construction
- Casing in aluminium alloy gravity casting, with non-sparking components
- Aluminium parts with anodic oxidation treatment and resin impregnation to ensure tightness and close any porosity
- Provision for pressure, vacuum, temperature and vibration sensors and for condensate drain
ATEX versions
- Zone 2 / 22 (category 3GD): marking II 3G c IIB T4 (gas) and II 3D c T135°C (dust), Ex nA motors with PTC sensor
- Gas conveying: marking II 3G cb IIB T3, vertical installation, anodized and impregnated parts, provision for temperature and pressure sensors and condensate drain hole
- Zone 1 / 21 (category 2GD), with flameproof Ex db motors and dust protection IP65
- ATEX-certified safety valve and filter, as required by the directive
Special Executions
- Magnetic drive version, completely sealed, for gas that must not be released
- Version with labyrinth seals and version with coupling
- Stainless steel construction and, on request, cast iron casing
- Surface treatments and PTFE coating for aggressive gases
- Motors with UL and CSA approvals and special voltages
Biogas and gases with H₂S
LCX blowers are suitable for conveying biogas and technical gases. General indications on hydrogen sulphide content:
- up to 2,000 ppm of H₂S: standard ATEX construction
- from 2,000 to 10,000 ppm: internal PTFE coating
- over 10,000 ppm: we recommend treating the gas upstream of the blower
Temperature, humidity, and shutdown cycles affect durability as much as concentration: for every plant, we evaluate the most suitable solution together with you.
Accessories
Safety valve · cartridge suction filter · gas filter · non-return valve · expansion joints · soundproof enclosure, also in ATEX version.
Applications
- Biogas recirculation and desulphurisation air dosing in biogas plants
- Aeration and oxygenation in treatment tanks
- Blowing and suction in industrial processes and machinery